Gas Detectors

ReAct 4

Product code: PW-093-RA4-X

The ReAct 4 gas detector is specifically designed for critical functions such as measuring, monitoring and detecting reactive gases in the surrounding atmosphere, with particular emphasis on aggressive or corrosive atmospheres.

See full description
Functionalities:
Certificates:
Product description
Technical details
Supported gases

The ReAct 4 gas detector is specifically designed for critical functions such as measuring, monitoring and detecting reactive gases in the surrounding atmosphere, with particular emphasis on aggressive or corrosive atmospheres. It can be installed in a variety of ways:

  • either integrated into the Gas Safety System Sigma Gas
  • or installed as a stand-alone detector, integrated with supervisory systems (e.g. by means of its 4…20mA output signal or its RS-485 interface).

The ReAct 4 detector has been developed to replace our earlier Sigma ReAct device. ReAct 4 is based on a completely new electronic design. It has a new measuring head HR with significantly improved measuring properties. It also is equipped with self diagnostics properties – user is immediately informed about the failure states.

 

Please visit our YouTube channel where you will learn about the properties of our devices:
Functionalities
WATCH THE ENTIRE PLAYLIST
Products
WATCH THE ENTIRE PLAYLIST
Realizations
WATCH THE ENTIRE PLAYLIST

 

 

Power supply
  • Voltage VCC

15 – 50 V

  • Power

0.3 – 4 W

Environment
  • Ambient temperatures

Specified depending on:

  • the temperature class of the
    device (see ATEX below),
  • device configuration, including the
    sensor used
  • 0 – 40°C ( Storage )
  • Humidity
  • 10 – 90% long term
  • 30 – 90% long term ( Storage )
  • 0 – 99% short term
    without condensation
  • Pressure

1013 ± 10% hPa

ATEX

II 3G Ex nA IIC T3 Gc

-40 ≤ Ta ≤ 50°C

IP

IP63

Analog output 4 – 20 mA
  • Output type
  • Sink / source
  • Rload_MAX (source mode)
  • 300 Ω
  • US_MAX (sink mode)
  • 30 V (max. voltage between pins „S” and „-”)
Digital output parameters
  • Relays

3 x Floating contacts, 24 V / 0.3 A
Not protected

Digital communication parameters
  • RS-485

RS-485, Modbus ASCII, Sigma Bus, od
19200 Bd 7E1

  • Teta

Teta Bus

Parameters of wireless communication

Bluetooth 4.2

Integrated signalling equipment (optical)

  • D=LCD: alphanumeric
    display 2×8
    of the LCD type with LED indicators
  • D=FLED: multicolour status display LED

Integrated signalling
equipment (audible)

D=FLED.A: 70 dB, 1 m distance

Protection class

III

Cable glands
  • Cable diameter range

See table with device configuration

  • External thread

E=ALB, ALZ, SS: M20 x 1,5

E=PES: M25 x 1,5

Acceptable cables

0.5 – 2.5 mm2
(cable lugs 2 x 1 mm2
or 2 x 0.75 mm2
should be used for double wires)

Enclosure material

See table with device configuration

Measuring head material

Stainless steel + PTFE

Weight

3.5 kg

Mandatory periodic
inspection

Every 12 months

(Calibration Certificate
validity)

time can be shortened due to
difficult working conditions

Mounting

  • E=ALB, ALZ, SS – to the supporting
    structure, 2 screw holes 4 mm, hole
    spacing 127 mm
  • E=ALB, ALZ,
    SS we recommend using mounting brackets
  • E=PES – to the supporting structure,
    4 screw holes for M6, hole spacing
    106 x 82 mm

Videos

Placement and role in the system

Files to download
Datasheets:
ReAct 4 Gas Detector - Datasheet
Download file
Users's manual:
ReAct 4 Gas Detector - User Manual
Download file
CE declarations:
ReAct 4 Gas Detector - Declaration of Conformity
Download file
Others:
Measurement parameters configuration of gas detectors
Download file
Skip to content
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.